ApprenticeLow risk

Motion-sensor light not working correctly

A sensor (PIR) light won't come on, stays on permanently, or triggers at the wrong times — common on eaves, garages, and entries.

Safety first

Isolate before adjusting or replacing the fitting. Outdoor fittings should be weatherproof — check seals when working on them.

Isolate, lock out / tag out, and prove dead before working unless a live test is specifically required, authorised, and carried out under proper supervision. Always follow local regulations, your site procedures, and the equipment manufacturer's documentation.

Apprentice mode

Full walk-through — the why, what readings mean, mistakes & safety.

Likely causes

Ranked from most to least likely.

  1. 1

    Mode / settings wrong (test, time, lux)

    Most likely

    Many PIR lights have test/auto modes, on-time, and daylight (lux) settings that, set wrong, cause odd behaviour.

  2. 2

    Sensor aimed/located poorly

    #2

    Wrong aim or range means it misses movement or triggers on traffic/animals.

  3. 3

    Daylight cut-off active

    #3

    Set to night-only, it won't activate in daylight (working as intended) — or the lux setting is wrong.

  4. 4

    Faulty sensor or lamp

    Least likely

    The PIR head or the lamp has failed.

Reports are saved on this device to reflect what you actually find.

Testing sequence

Work through one test at a time. Expected reading and what each result means.

On the tools? Job Mode shows one test at a time with thumb-sized buttons — your place and readings carry straight over.

Enter Job Mode
Test 1 of 3
1

Check the mode and settings (test mode, on-time, lux/daylight) match what you expect.

Expected reading

Settings consistent with the desired behaviour.

If it passes

Settings fine — check aim/range and the lamp/sensor.

If it fails

Wrong mode/settings — set them correctly and re-test.

Mark this test
View all expected readings at once
1. Check the mode and settings (test mode, on-time, lux/daylight) match what you expect.
Settings consistent with the desired behaviour.
2. Check the sensor's aim, range, and that the daylight cut-off isn't preventing daytime testing.
Sensor covers the right area; tested in suitable light.
3. Isolate and test the lamp and sensor head (swap/replace as needed).
Working lamp and responsive sensor.

Fault-finding flowchart

The same logic as a decision tree.

  1. 1
    start

    Sensor light faulty

    → step 2
  2. 2
    decision

    Are mode and settings (time/lux) correct?

    Yes→ step 3No→ step 4
  3. 3
    decision

    Is the aim/coverage right (and tested in suitable light)?

    Yes→ step 5No→ step 6
  4. 4
    result

    Set the correct mode/settings and re-test.

  5. 5
    decision

    Do the lamp and sensor head test healthy?

    Yes→ step 7No→ step 8
  6. 6
    result

    Re-aim/relocate the sensor.

  7. 7
    result

    Re-verify settings/aim.

  8. 8
    result

    Faulty lamp/sensor — replace.

Common mistakes apprentices make

  • Testing in daylight when the lux setting blocks daytime operation.
  • Leaving it in test mode (short on-time) and thinking it's faulty.
  • Poor aim so it misses the intended approach.
  • Replacing the fitting before checking the settings.

When to stop & escalate

Replacement and any wiring is licensed electrical work. Persistent false triggers from a fundamentally poor location may need the fitting repositioned.

If you're past your competence, authorisation, or the safe limits of the job — stop and hand it on. There's no fault worth getting hurt over.

Was this guide helpful?