QualifiedMedium risk

Lights flickering

One or more lights flicker — constantly, intermittently, or when other appliances run. Common with LEDs and dimmers, but can also signal a loose connection.

Safety first

Flicker from a loose connection can mean local heating — treat it seriously, not just as an annoyance. Isolate before investigating connections.

Isolate, lock out / tag out, and prove dead before working unless a live test is specifically required, authorised, and carried out under proper supervision. Always follow local regulations, your site procedures, and the equipment manufacturer's documentation.

Apprentice mode

Full walk-through — the why, what readings mean, mistakes & safety.

Likely causes

Ranked from most to least likely.

  1. 1

    Incompatible LED / dimmer combination

    Most likely

    Many LEDs flicker on dimmers (or even some switches) they aren't matched to — a very common modern cause.

  2. 2

    Loose connection in the lighting circuit

    #2

    A loose terminal at a rose, switch, or junction causes intermittent flicker and can overheat.

  3. 3

    Voltage dip when a large appliance starts

    #3

    Lights dimming/flickering when a motor (aircon, pump) starts points at inrush/voltage drop.

  4. 4

    Failing lamp / driver

    #4

    An LED or driver near end of life can flicker before it fails.

  5. 5

    Loose or high-resistance neutral

    Least likely

    A neutral problem can cause flicker across multiple lights — see lost-neutral fault-finding.

Reports are saved on this device to reflect what you actually find.

Testing sequence

Work through one test at a time. Expected reading and what each result means.

On the tools? Job Mode shows one test at a time with thumb-sized buttons — your place and readings carry straight over.

Enter Job Mode
Test 1 of 3
1

Note the pattern: one fitting or many? Constant, or only when something switches on?

Expected reading

A pattern pointing to lamp/dimmer vs wiring vs supply.

If it passes

One fitting on a dimmer → suspect compatibility. Many/when appliances run → wiring/supply.

If it fails

If random across the house, suspect a neutral or supply issue.

Mark this test
View all expected readings at once
1. Note the pattern: one fitting or many? Constant, or only when something switches on?
A pattern pointing to lamp/dimmer vs wiring vs supply.
2. For a dimmed/LED fitting, check the LED and dimmer are a compatible (trailing-edge/LED-rated) combination.
Compatible, LED-rated dimmer and lamps.
3. Isolate and check connections at the affected fittings, switches, and any junctions for tightness/heat.
Tight, cool connections.

Fault-finding flowchart

The same logic as a decision tree.

  1. 1
    start

    Lights flickering

    → step 2
  2. 2
    decision

    Is it one dimmed/LED fitting (vs many / when appliances run)?

    Yes→ step 3No→ step 4
  3. 3
    decision

    Are the LED and dimmer a compatible combination?

    Yes→ step 5No→ step 6
  4. 4
    result

    Many/with appliances — check connections, supply, and neutral.

  5. 5
    decision

    Are the connections tight and cool?

    Yes→ step 7No→ step 8
  6. 6
    result

    Mismatch — fit compatible LED-rated lamps/dimmer.

  7. 7
    result

    Investigate supply/neutral or a failing lamp/driver.

  8. 8
    result

    Loose/hot connection — remake it.

Common mistakes apprentices make

  • Assuming a wiring fault when it's an LED/dimmer compatibility issue.
  • Ignoring flicker that coincides with a loose, heating connection.
  • Not noticing flicker only happens when a big appliance starts.
  • Overlooking a neutral problem when many lights flicker together.

When to stop & escalate

Flicker traced to a loose/heating connection or a neutral fault needs prompt repair by a licensed electrician (fire risk). Persistent flicker when large appliances start may indicate supply/voltage-drop issues to assess.

If you're past your competence, authorisation, or the safe limits of the job — stop and hand it on. There's no fault worth getting hurt over.

Was this guide helpful?

Related faults

Learn the theory

How the gear and circuits behind this fault actually work.